The SF Series are rugged and reliable traditional salt fog (spray) and humidity cabinets. SF cabinets are used to quickly qualify a coating or material on a pass-fail basis, or determine the probability of corrosion of a specific material.
Typical standards met by the SF Series include Traditional Salt Fog & Humidity Tests: ASTM B117, ASTM D1735, ISO9227, GM 4429P, GM 4465P, CASS, SWAAT, Acetic acid, Water, Humidity, etc.
With Humidity Test Kit: non-condensing humidity tests including ASTM D2247, FLTMA BQ4-2, Corrodcote™.
With Microprocessor-based Control Package: for basic cyclic Fog/Purge tests except ASTM G85 Annex 5 (Prohesion™) which requires the BCX: for SO2 exposure tests including ASTM G85 Annex 4, ISO 6988.
With SO2 Injection System for SO2 exposure tests including ASTM G85 Annex 4, ISO 6988.
SF applications include: Architectural, Chrome Plating, Fasteners, Government, Metals, Military, Paints/Coatings, Laminated/Coated Plastics and Steel Structures.
-
Features–
Specifications and Dimensions (Testing Volume, Exposure Zone Dimensions, External Dimensions):
- SF260 – 420L, 0.76 x 0.56 x 0.99 m, 1.07 x 0.97 x 1.52 m
- SF500 – 555L, 0.76 x 0.74 x 0.99 m, 1.22 x 1.07 x 1.52 m
- SF850 – 860L, 1.14 x 0.76 x 0.99 m, 1.57 x 1.07 x 1.52 m
- SF2000 – 1930L, 1.83 x 1.07 x 0.99 m, 2.44 x 1.37 x 21.60 m
- SF3600 – 2850L, 2.36 x 1.22 x 0.99 m, 3 x 1.52 x 1.60 m
- SF4200 – 3680L, 3.05 x 1.22 x 0.99 m, 3.81 x 1.52 x 1.60 m
Standard features for SF cabinets include:
- Durable steel cabinet with 55 gal (208 L) solution reservoir with mixing system on stand
- Cabinet heated by water jacket on four sides and bottom
- Exposure zone lined with corrosion-resistant PVC sheets
- Clear cover allows viewing of test conditions
- Peaked cover prevents dripping of condensation onto samples
- Water seal
- Heated humidifying tower with air relief valve
- Automatic DI water fill to humidifying tower
- Automatic solution level control
- Digital temperature control and readouts
- Certified air pressure gauge accurate to 1 psi (6.9 kPa)
- Integral over-protection on all heaters
- Low water cut-off protection on humidifying tower
- Two digital temperature controllers
- Display Graphing on Notebook Monitor (PC not included)
- Operator Interface/Datalogging Software
- Pressure Transducer for Bubble Tower
- Solution Reservoir Fill with Automatic Shut-off
-
Options–
- Recorder, 2-pen circular chart, wet bulb and dry bulb
- UL approval
- Shut-down timer
- SF combination exhaust condenser and wet bottom drain
- SF exhaust recirculation system
- Precision air regulator, accurate to 0.01 psi (0.069 kPa)
- External collection package. Horizontal dispersion system
- High temperature package
- Chromasoft software
- High voltage kit (over 480 VAC)
- High capacity oil & water extractor
- Custom sizes (extra height or any LxW) and configurations (pass-through electrical/mechanical ports)
-
Applications–